Dimensions & Standard Packing
Size ( in mm ) | Sizes ( in inches ) | Sch-40 (3 mtr) | Sch-40 (6 mtr) | Sch-80 (3 mtr) | Sch-80 (6 mtr) |
---|---|---|---|---|---|
15mm | 1⁄2" | 60 | 30 | 50 | 26 |
20mm | 3⁄4" | 44 | 24 | 36 | 18 |
25mm | 1” | 30 | 16 | 26 | 14 |
32mm | 1 1⁄4" | 24 | 12 | 18 | 10 |
40mm | 1 1⁄2" | 20 | 10 | 14 | 8 |
50mm | 2” | 14 | 8 | 10 | 6 |
65mm | 2 1⁄2" | 9 | 4 | 8 | 4 |
80mm | 3” | 7 | 3 | 6 | 3 |
100mm | 4" | 5 | 2 | 4 | 2 |
150mm | 6" | 2 | 1 | 2 | 1 |
Fittings | Pipes | |
---|---|---|
Material | Unplasticized Polyvinyl Chloride (UPVC) with U.V. Resistance | Unplasticized Polyvinyl Chloride (UPVC) with U.V. Resistance |
Colour | White | White |
Refernce Standards | Sch- 80 as per ASTM D- 2467 Sch- 40 as per ASTM D- 2466 | Sch- 40 , 80 & 120 s per ASTM D- 1785 |
Working Temperature | Upto 60 degree- Continous Upto - 90 degree- Short Time- upto 3 mins | Unplasticized Polyvinyl Chloride (UPVC) with U.V. Resistance |
End Connections | Solvent sockets. For transition joints, fittings with plastic theaded & metal threaded inserts available | Solvent Joint |
It is imperative to mark the pipe from all sides so that pipe is cut with the help of a Hand Saw. It should be a right angle cut from all the sides. The cut piece should not be with burr on edges
After cutting, the pipe needs to be chamfered from the outer sides. It is advisable to provide approximately 2mm wide, 150 chamfer on spigot end
Remove all the burrs and ridges accumulated on the inner as well as the outer edges of the pipe with the help of a deburring knife, file or abrasive paper.
Before applying solvent cement, insert the pipe end into the socket of the next pipe or fitting to check that interference occurs at about 1/3 to 2/3 of the socket depth.
Thoroughly clean the pipe with dry cloth where the solvent cement is going to be applied to avoid dust, dirt, oil, moisture and other foreign material during the installation process.
Mark the pipe length to be inserted for jointing. Apply a liberal coat of solvent cement with the help of the brush on the marked surface
Push the pipe inside the fitting/pipe so that it goes inside equally from all the sides. Wipe off excess solvent cement that comes out of the edges. Hold the joint for one to two minutes so that the jointing is perfect.
• Clean the Male & Female threads.
• Apply teflon tape in the direction of thread tightening.
• Hand-tighten the threads firmly.
• Tighten the joint more by using pipe wrench. Do not over tighten. Use rubber packing to avoid scratches on pipe.
Do not cut slant/unevenly.
Do not proceed with installation of pipe without chamfering.
Do not proceed with installation of pipe without deburring.
Do not apply solvent cement without dryfit test.
Do not join the pipes without cleaning the pipe ends.
Do not apply excess solvent cement on the pipe and do not use solvent cement by hand.
• Do not apply excess solvent cement on the pipe.
• Do not use a hammer or half push the pipes.
Don't over tighten with pipe wrench